KENWOOD AIR CONDITION - CASSETTE PANEL NON-INVERTER ONLY COOL
Click to enlarge
-47%

in stock

KENWOOD AIR CONDITION - CASSETTE PANEL NON-INVERTER ONLY COOL

sold in last hours
Vendor: KENWOOD
SKU: KCT-2401H
Rs.698,400 Rs.365,000
CASSETTE PENAL:
Order in The Next to get it by
Spend $200 to get Free Shipping

Categories: AC - CASSETTE TYPE,

Tags:

Kenwood non-inverter ceiling cassette

The Kenwood Non-Inverter ceiling cassette is expertly constructed for low-noise operation. In the industry, Kenwood is a market leader and a significant global player. The extraordinary climatic conditions of the Kenwood -ton non-inverter ceiling cassette are very advantageous for medium- to large-scale situations.

Advantages

The Kenwood ceiling cassette’s non-versatility, inverter’s built-in drain pump, 360° airflow, ultra-slim design, and fresh air intake make it essential for creating the ideal ambiance. In contrast to typical heat pump split systems, the Kenwood -tone non-inverter cassette KCT ceiling adapts its performance in response to shifting demand.

Offers

Several distinguishing features of the Kenwood 1.5-Ton Non-Inverter Ceiling Cassette include

  • Super slim design
  • 360° Airflow
  • Fresh air intake
  • Easy installation
  • Low noise design
  • Built-in drain pump
  • Reserved air outlet for duct
  • Reserved remote on-off and alarm ports

This considerably simplifies your daily activities. The list below includes a discussion of a number of them.

Low-noise design

Little noise is made by the Kenwood Non-Inverter Ceiling Cassette KCT. Using low-noise components and operating points allows designers to reduce irrelevant noise. Other design objectives, such as power gain and electrical resistance matching, must be balanced in order to reduce unnecessary noise.

Intake of fresh air

The system may take in fresh air from the outside thanks to a fresh air intake. Your home must have a fresh air inlet if appliances like a Kenwood - non-inverter are installed.

Reserved duct air outlet

Ducts are tubes or passageways used in heating, ventilation, and air conditioning for the distribution and removal of air. For things like supply, return, and exhaust air, ducts need a dedicated air outlet. Ducts frequently also deliver ventilation air in addition to supply air.

Closing phrases

The best products for your daily necessities may be found at Izyan Homet. If you’re in need of Kenwood’s non-inverter ceiling cassette 1, don’t be afraid to get in touch with Izyan Home. The top products are offered at Freeze Point at reasonable rates.

 

      KCT-2401H KCT-4801H
Product Specification Supplier Specification Supplier Specification
Power supply    (Indoor )   V- Ph-Hz 220-240V,1Ph,50Hz 380-415V,3Ph,50Hz
Power supply    (Outdoor )   V- Ph-Hz 220-240V,1Ph,50Hz 380-415V,3Ph,50Hz
Cooling (Standard conditions) Capacity                      Btu/h 24000(0~0) 48000(/~/)
  Input            W 2600(0~0) 5191(/~/)
  Current    A 11.3(0~0) 9.2(/~/)
Heating (Standard conditions) Capacity         Btu/h 26000(0~0) 52000(/~/)
  Input            W 2200(0~0) 4763(/~/)
  Current    A 9.6(0~0) /(/~/)
Rated Power Input          W 3700 6300
Rated Current                  A 18 11.0
Starting current                  A 54.9 66
Indoor fan motor Model    YKT-30-6-1 YKT-80-6-6
  Qty   1 1
  Input            W / /
  Capacitor        uF 3 4.5
  Speed(Hi/Mi/Lo) r/min 620/480/410 760/690/610
Indoor coil a.Number of rows   2 3
  b.Tube pitch(a)x row pitch(b)   mm 21x13.37 21x13.37
  c.Fin spacing                 mm 1.3 1.3
  d.Fin type (code)   Hydrophilic aluminum Hydrophilic aluminum
  e.Tube outside dia.and type  mm Φ7,Inner groove tube Φ7,Inner groove tube
  f.Coil length x height x width   mm 2155x168x26.74 2135*210*13.37+2065*210*13.37+1995*210*13.37
  g.Number of circuits   4 10
Indoor air flow (Hi/Mi/Lo)   m3/h 1300/1000/820 1916/1780/1620
Indoor noise level (Hi/Mi/Lo)   dB(A) 45.5/40/37.5 54/52/50
Indoor sound power level   dB(A) / /
Throttle type   / 外机节流 外机节流
Indoor unit Dimension(W*D*H)(body) mm 830x830x205 830x830x245
  Dimension (W  x Dx H)(panel) mm 950x950x55 950x950x55
  Packing   (W*D*H)(body) mm 910x910x250 910x910x290
  Packing  (W  x Dx H)(panel) mm 1035x1035x90 1035x1035x90
  Net/Gross weight(body) kg 22.2/26.2 28.3/32.3
  Net/Gross weight(panel) kg 6/9 6/9
Drainage water pipe dia   mm ODΦ25mm ODΦ25mm
Qty’per 20’ /40’ /40'HQ        Indoor unit 108/234/260 96/208/234
Compressor Model    KTG275V2VMP C-SBN373H8D
  Type    ROTARY SCROLL
  Brand    GMCC PANASONIC
  Capacity      W 8470 14100/17100
  Input           W 2015 4750/5600
  Rated current(RLA)  A 9.2 8.22/8.30
  Locked rotor Amp(LRA)    A 55 66.0
  Thermal protector    内置 /
  Thermal protector position   INTERNAL INTERNAL
  Capacitor       μF 65.0 /
  Refrigerant oil/oil charge   ml VG74  750ml FV68S/1700
Outdoor fan motor Model    YKT-65-6-240L YKT-65-6-34L
  Qty   系统自行查询 系统自行查询
  Input            W 135.0 162.0
  Capacitor        uF 5 3.5uf
  Speed         r/min 825 765
Outdoor coil a.Number of rows   1.6 2
  b.Tube pitch(a)x row pitch(b)   mm 21x13.37 21x22
  c.Fin spacing                 mm 1.3 1.3
  d.Fin type (code)   Hydrophilic aluminum Hydrophilic aluminum
  e.Tube outside dia.and type  mm Ф7,Inner groove tube Ф7,Inner groove tube
  f.Coil length x height x width   mm 900*26.74*609 830*630*22+795*630*22
  g.Number of circuits   5 8
Outdoor air flow               m3/h 3650 6000
Outdoor sound pressure level   dB(A) 60 62
Outdoor sound power level           dB(A) / /
Throttle type   / 节流阀(Throttle valve) 节流阀(Throttle valve)
Outdoor unit Dimension(W*D*H) mm 890x342x673 900x350x1170
  Packing  (W*D*H) mm 995x398x740 1032x443x1307
  Net/Gross weight   kg 52.9/55.9 98.6/109.3
Refrigerant           Type    R410A R410A
  GWP   2088 2088
  Charged quantity kg 2.0 3.3
Design pressure                MPa 4.2/1.5 4.2/1.5
Refrigerant piping Liquid side/ Gas side   mm(inch) 9.52mm(3/8in)/15.9mm(5/8in) 9.52mm(3/8in)/19mm(3/4in)
  Max. refrigerant pipe length    m 25 50
  Max. difference in level        m 15 30
Thermostat type     遥控式(Remote Control) 遥控式(Remote Control)
Room  temperature Indoor(cooling/ heating) 17~32/0~30 17~32/0~30
  Outdoor(cooling/heating) 18~43/-7~24 18~43/-7~24
Application area   (Cooling Standard)   m2 32~47 64~94
Qty’per 20’ /40’ /40'HQ        Outdoor unit 99/198/198 27/57/108