in stock
KENWOOD AIR CONDITION - CASSETTE PANEL NON-INVERTER ONLY COOL
Kenwood non-inverter ceiling cassette
The Kenwood Non-Inverter ceiling cassette is expertly constructed for low-noise operation. In the industry, Kenwood is a market leader and a significant global player. The extraordinary climatic conditions of the Kenwood -ton non-inverter ceiling cassette are very advantageous for medium- to large-scale situations.
Advantages
The Kenwood ceiling cassette’s non-versatility, inverter’s built-in drain pump, 360° airflow, ultra-slim design, and fresh air intake make it essential for creating the ideal ambiance. In contrast to typical heat pump split systems, the Kenwood -tone non-inverter cassette KCT ceiling adapts its performance in response to shifting demand.
Offers
Several distinguishing features of the Kenwood 1.5-Ton Non-Inverter Ceiling Cassette include
- Super slim design
- 360° Airflow
- Fresh air intake
- Easy installation
- Low noise design
- Built-in drain pump
- Reserved air outlet for duct
- Reserved remote on-off and alarm ports
This considerably simplifies your daily activities. The list below includes a discussion of a number of them.
Low-noise design
Little noise is made by the Kenwood Non-Inverter Ceiling Cassette KCT. Using low-noise components and operating points allows designers to reduce irrelevant noise. Other design objectives, such as power gain and electrical resistance matching, must be balanced in order to reduce unnecessary noise.
Intake of fresh air
The system may take in fresh air from the outside thanks to a fresh air intake. Your home must have a fresh air inlet if appliances like a Kenwood - non-inverter are installed.
Reserved duct air outlet
Ducts are tubes or passageways used in heating, ventilation, and air conditioning for the distribution and removal of air. For things like supply, return, and exhaust air, ducts need a dedicated air outlet. Ducts frequently also deliver ventilation air in addition to supply air.
Closing phrases
The best products for your daily necessities may be found at Izyan Homet. If you’re in need of Kenwood’s non-inverter ceiling cassette 1, don’t be afraid to get in touch with Izyan Home. The top products are offered at Freeze Point at reasonable rates.
KCT-2401H | KCT-4801H | |||
Product Specification | Supplier Specification | Supplier Specification | ||
Power supply (Indoor ) | V- Ph-Hz | 220-240V,1Ph,50Hz | 380-415V,3Ph,50Hz | |
Power supply (Outdoor ) | V- Ph-Hz | 220-240V,1Ph,50Hz | 380-415V,3Ph,50Hz | |
Cooling (Standard conditions) | Capacity | Btu/h | 24000(0~0) | 48000(/~/) |
Input | W | 2600(0~0) | 5191(/~/) | |
Current | A | 11.3(0~0) | 9.2(/~/) | |
Heating (Standard conditions) | Capacity | Btu/h | 26000(0~0) | 52000(/~/) |
Input | W | 2200(0~0) | 4763(/~/) | |
Current | A | 9.6(0~0) | /(/~/) | |
Rated Power Input | W | 3700 | 6300 | |
Rated Current | A | 18 | 11.0 | |
Starting current | A | 54.9 | 66 | |
Indoor fan motor | Model | YKT-30-6-1 | YKT-80-6-6 | |
Qty | 1 | 1 | ||
Input | W | / | / | |
Capacitor | uF | 3 | 4.5 | |
Speed(Hi/Mi/Lo) | r/min | 620/480/410 | 760/690/610 | |
Indoor coil | a.Number of rows | 2 | 3 | |
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | 21x13.37 | |
c.Fin spacing | mm | 1.3 | 1.3 | |
d.Fin type (code) | Hydrophilic aluminum | Hydrophilic aluminum | ||
e.Tube outside dia.and type | mm | Φ7,Inner groove tube | Φ7,Inner groove tube | |
f.Coil length x height x width | mm | 2155x168x26.74 | 2135*210*13.37+2065*210*13.37+1995*210*13.37 | |
g.Number of circuits | 4 | 10 | ||
Indoor air flow (Hi/Mi/Lo) | m3/h | 1300/1000/820 | 1916/1780/1620 | |
Indoor noise level (Hi/Mi/Lo) | dB(A) | 45.5/40/37.5 | 54/52/50 | |
Indoor sound power level | dB(A) | / | / | |
Throttle type | / | 外机节流 | 外机节流 | |
Indoor unit | Dimension(W*D*H)(body) | mm | 830x830x205 | 830x830x245 |
Dimension (W x Dx H)(panel) | mm | 950x950x55 | 950x950x55 | |
Packing (W*D*H)(body) | mm | 910x910x250 | 910x910x290 | |
Packing (W x Dx H)(panel) | mm | 1035x1035x90 | 1035x1035x90 | |
Net/Gross weight(body) | kg | 22.2/26.2 | 28.3/32.3 | |
Net/Gross weight(panel) | kg | 6/9 | 6/9 | |
Drainage water pipe dia | mm | ODΦ25mm | ODΦ25mm | |
Qty’per 20’ /40’ /40'HQ | Indoor unit | 108/234/260 | 96/208/234 | |
Compressor | Model | KTG275V2VMP | C-SBN373H8D | |
Type | ROTARY | SCROLL | ||
Brand | GMCC | PANASONIC | ||
Capacity | W | 8470 | 14100/17100 | |
Input | W | 2015 | 4750/5600 | |
Rated current(RLA) | A | 9.2 | 8.22/8.30 | |
Locked rotor Amp(LRA) | A | 55 | 66.0 | |
Thermal protector | 内置 | / | ||
Thermal protector position | INTERNAL | INTERNAL | ||
Capacitor | μF | 65.0 | / | |
Refrigerant oil/oil charge | ml | VG74 750ml | FV68S/1700 | |
Outdoor fan motor | Model | YKT-65-6-240L | YKT-65-6-34L | |
Qty | 系统自行查询 | 系统自行查询 | ||
Input | W | 135.0 | 162.0 | |
Capacitor | uF | 5 | 3.5uf | |
Speed | r/min | 825 | 765 | |
Outdoor coil | a.Number of rows | 1.6 | 2 | |
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | 21x22 | |
c.Fin spacing | mm | 1.3 | 1.3 | |
d.Fin type (code) | Hydrophilic aluminum | Hydrophilic aluminum | ||
e.Tube outside dia.and type | mm | Ф7,Inner groove tube | Ф7,Inner groove tube | |
f.Coil length x height x width | mm | 900*26.74*609 | 830*630*22+795*630*22 | |
g.Number of circuits | 5 | 8 | ||
Outdoor air flow | m3/h | 3650 | 6000 | |
Outdoor sound pressure level | dB(A) | 60 | 62 | |
Outdoor sound power level | dB(A) | / | / | |
Throttle type | / | 节流阀(Throttle valve) | 节流阀(Throttle valve) | |
Outdoor unit | Dimension(W*D*H) | mm | 890x342x673 | 900x350x1170 |
Packing (W*D*H) | mm | 995x398x740 | 1032x443x1307 | |
Net/Gross weight | kg | 52.9/55.9 | 98.6/109.3 | |
Refrigerant | Type | R410A | R410A | |
GWP | 2088 | 2088 | ||
Charged quantity | kg | 2.0 | 3.3 | |
Design pressure | MPa | 4.2/1.5 | 4.2/1.5 | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | 9.52mm(3/8in)/15.9mm(5/8in) | 9.52mm(3/8in)/19mm(3/4in) |
Max. refrigerant pipe length | m | 25 | 50 | |
Max. difference in level | m | 15 | 30 | |
Thermostat type | 遥控式(Remote Control) | 遥控式(Remote Control) | ||
Room temperature | Indoor(cooling/ heating) | ℃ | 17~32/0~30 | 17~32/0~30 |
Outdoor(cooling/heating) | ℃ | 18~43/-7~24 | 18~43/-7~24 | |
Application area (Cooling Standard) | m2 | 32~47 | 64~94 | |
Qty’per 20’ /40’ /40'HQ | Outdoor unit | 99/198/198 | 27/57/108 |